詳細介紹
耐壓實驗部分
輸出電壓AC/DC | AC0.2~5.00kV,500VA(額定30分鐘)/DC0.2~5.00kV,50VA(連續(xù)) |
---|---|
電壓設置方式 | 數(shù)字設置(設置分辨率:0.01kV) |
AC波形/頻率 | 正弦波(無負載時畸變率在5%以下),可以在50/60Hz切換 |
電流測量范圍 | 10mA,分辨率:0.01mA / 100mA,分辨率:0.1mA |
電壓計 | 精度:±1.5%f.s.(JIS 1.5級,f.s.=5.00kV)(有效值顯示) |
判定方式 | 窗口比較方式(數(shù)字設定) |
絕緣電阻試驗
額定電壓 | DC50~1200V(1V步進的話可任意設置) |
---|---|
額定測試電流 | 1mA,短路電流:200mA以下 |
測試范圍/精度 | 0.10 ~9999 MΩ, 4檔量程, ±4 % rdg. (代表值 0.5 MΩ~1000 MΩ時) |
判定方式 | 窗口比較方式(數(shù)字設定) |
計時器 *實際試驗時會因為負載的不同而導致定時器設定時間的不同
設置范圍 | 0.3~999 s |
---|---|
Ramp/Delay | 測試電壓Ramp up、down,絕緣電阻試驗延遲:0.1~99.9s |
功能 | 最多可對32個文件進行50步進的實驗設置的編程 各保存10組耐壓/絕緣的試驗內(nèi)容,保持,蜂鳴器 |
監(jiān)測功能 | 輸出電壓、檢測電流/測試電阻,監(jiān)測周期:2次/s以上 |
電源 | AC100~240V(50/60Hz),1000VA max. |
體積/重量 | 320W×155H×480D mm,18kg |
附件 | 9615高壓測試線(高壓線和回路,各1),電源線×1,使用說明書×1,備用保險絲×1 |
Voltage withstanding test part
Output voltage AC/DC AC0.2-5.00kV, 500VA (rated 30 minutes)/DC0.2-5.00kV, 50VA (continuous)
Voltage Setting Mode Digital Setting (Setting Resolution: 0.01 kV)
AC waveform/frequency sinusoidal wave (distortion rate below 5% without load) can be switched at 50/60 Hz
Current measurement range is 10 mA, resolution: 0.01 mA/100 mA, resolution: 0.1 mA.
Voltmeter accuracy: +1.5% F.S. (JIS 1.5, F.S. = 5.00kV) (RMS display)
Decision mode, window comparison mode (digital setting)
Insulation resistance test
Rated voltage DC50~1200V (1V step can be set arbitrarily)
Rated test current 1 mA, short circuit current below 200 mA
The test range/accuracy is 0.10~9999 M_, 4 ranges, +4% rdg. (when the representative value is 0.5 M_~1000 M_)
Decision mode, window comparison mode (digital setting)
Timer * The actual test will result in different timer settings due to different loads
Setting range 0.3-999 s
Ramp/Delay test voltage Ramp up and down, insulation resistance test delay: 0.1-99.9s
Function: Programming of experimental setup of up to 50 steps for 32 files
Preserve 10 groups of test contents of withstanding voltage/insulation, hold, buzzer
Monitoring function: output voltage, detection current/test resistance, monitoring period: more than 2 times/s
Power supply: AC100-240V (50/60Hz), 1000VA max.
Volume/weight 320W*155H*480D mm, 18kg
Annex 9615 High Voltage Test Wire (High Voltage Wire and Loop, 1 each), Power Wire *1, Instruction *1, Standby Fuse *1