廈門(mén)阿米控技術(shù)有限公司

主營(yíng)產(chǎn)品: 1756-L62,140CPU11302,07KT98,IC693CPU374,3805E

您現(xiàn)在的位置: 廈門(mén)阿米控技術(shù)有限公司>>AB羅克韋爾模塊>> 1756-M02AE1756-M02AE【M02AE】

公司信息

聯(lián)人:
許小燕
址:
廈門(mén)市思明區(qū)湖濱南路388號(hào)國(guó)貿(mào)大廈32D單元
編:
361000
鋪:
http://thanksk.cn/st43200/
給他留言
1756-M02AE1756-M02AE【M02AE】
1756-M02AE【M02AE】
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號(hào) 1756-M02AE
  • 品牌
  • 廠商性質(zhì) 經(jīng)銷(xiāo)商
  • 產(chǎn)品資料 下載
  • 所在地 廈門(mén)市

聯(lián)系方式:許小燕查看聯(lián)系方式

更新時(shí)間:2017-06-05 20:14:03瀏覽次數(shù):3545

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是制藥網(wǎng)上看到的信息,謝謝!

【簡(jiǎn)單介紹】
1756-M02AE 1756-M02AE 1756-M02AE
【詳細(xì)說(shuō)明】

Publication 1747-UM011G-EN-P - June 2008
Loss of Power Source
The chassis power supplies are designed to withstand brief power losses 
without affecting the operation of the system. The time the system is 
operational during power loss is called program scan hold-up time after loss of 
power. The duration of the power supply hold-up time depends on the 
number, type, and state of the I/O modules, but is typically 20 ms...3 s. When 
the duration of power loss reaches a limit, the power supply signals the 
processor that it can no longer provide adequate dc power to the system. This 
is referred to as a power supply shutdown. The power supply status indicator is 
turned off.
In multi-chassis systems, power outages of 20...300 ms in duration can cause a 
remote power fail error to occur. You can clear this error by cycling power to 
your system or by using a programming device.
Input States on Power Down
The power supply hold-up time as described above is generally longer than the 
turn-on and turn-off times of the input modules. Because of this, the input 
state change from On to Off that occurs when power is removed may be 
recorded by the processor before the power supply shuts down the system. 
Understanding this concept is important.Write the user program to take this 
effect into account. For example, hard-wire power to one spare input. In the 
user program, check to be sure that one input is on; otherwise, jump to the end 
of the program and avoid scanning the logic. Use of a common power source 
as recommended in the previous section is assumed.
Power Supply Undervoltage Operation
SLC 500 controllers continue to operate (hold-up) for a short period of time if 
the input voltage to the power supply drops below the recommended 
operating voltage range. The controller continues to scan the user program 
and control I/O during this time. CPU hold-up time is 20 ms...3 s depending 
on the power supply and loading.
SLC 500 controllers turn OFF (stop scanning and disable outputs) if input 
voltage to the power supply is removed or drops below the recommended 
operating range for a period exceedingthe CPU hold-up time. The controller 
resumes operation automatically when the input voltage is restored to normal.
If the input voltage to the 1746-P7 power supply falls into a range of 4...9V for 
a period exceeding the CPU hold-up time, the controller turns OFF and will 
not turn back ON until the input voltage is increased to 11V dc.Control Techniques CTIU100K-001
Control Techniques C80010
Control Techniques CD 400
Control Techniques CD 750
Control Techniques CDL03 AC Drive 240v 3hp
Control Techniques CDLII05 DRIVE
Control Techniques CDE15HPICD
Control Techniques CDE 550
Control Techniques CDVE50HP 9650-8150
Control Techniques DCD60X7
Control Techniques DIN1220150B DIN 1220150B
Control Techniques DIN3380110B
Control Techniques DIN3380220B #6736bLR
Control Techniques SP1403
Control Techniques SP2402 SP 2402 
Control Techniques SKBD200150
Control Techniques SP1201 SP 1201
Control Techniques SP1401
Control Techniques SP1402-LED 
Control Techniques SP1403-LED SP1403LED
Control Techniques SP1403 SP 1403

 

1756-M02AE  1756-M02AE  1756-M02AE   
**********************************************************

全國(guó)zui大的備件庫(kù)!---------:張可可
選擇zui有權(quán)利的公司!-----:
選擇*的質(zhì)量!--------
選擇的產(chǎn)品!---------
選擇的服務(wù)!------------
選擇zui快的貨期!---------------:
選擇*的價(jià)格!------------------:

**************************************************************


Control Techniques SP1404 SP 1404
Control Techniques SP1405
Control Techniques SP1406
Control Techniques SP1406-LED-PICO
Control Techniques SP2203
Control Techniques SP2401 
Control Techniques SP2402 
Control Techniques SP3202 SP-3202 
Control Techniques SP5402-LED
Control Techniques SM-Ethernet
Control Techniques SM-Applications



產(chǎn)品對(duì)比 二維碼

掃一掃訪問(wèn)手機(jī)商鋪

對(duì)比框

在線留言