【廣州★洋奕】做好產(chǎn)品包裝工作,保障產(chǎn)品zui終質(zhì)量,專業(yè)提供【LCD-45.4t】稱重傳感器,原裝*,質(zhì)量保證,貨期短,LCD-45.4t傳感器打造*傳感器品牌,訂購方便,還可以享受當?shù)貍€性化支持,免費,訂購。
美國CELTRON STC稱重傳感器S型稱重傳感器:
STC-5kg,STC-10kg,STC-25kg,STC-50kg,STC-75kg,STC-100kg,STC-250kg,STC-500kg,STC-750kg,STC-1t,STC-1.5t,STC-2t,STC-2.5t,STC-5t,STC-7.5t,STC-10t,STC-20t
STC-50kgSS,STC-75kgSS,STC-100kgSS,STC-250kgSS,STC-500kgSS,STC-750kgSS,STC-1t SS,STC-1.5Tss,STC-2tSS,STC-2.5tSS,STC-5tSS,STC-7.5tSS,STC-10tSS,STC-20tSS
STC-50kgXS,STC-75kgXS,STC-100kgXS,STC-250kgXS,STC-500kgXS,STC-750kgXS
STC-50lb,STC-100lb,STC-150lb,STC-200lb,STC-300lb,STC-500lb,STC-750lb,STC-1Klb,STC-1.5Klb,STC-2Klb,STC-2.5Klb,STC-3Klb,STC-5Klb,STC-7.5Klb,STC-10Klb,STC-15Klb,STC-30Klb,STC-40Klb
美國CELTRON DSR/DSR-SS梁式稱重傳感器:
DSR-1Klb,DSR-1.5Klb,DSR-2Klb,DSR-2.5Klb,DSR-3.5Klb,DSR-10Klb,DSR-15Klb,DSR-20Klb,KDR-25Klb,DSR-50Klb,DSR-75Klb
DSR-5KSS,DSR-10KSS,DSR-25KSS,DSR-50KSS,DSR-75KSS,DSR-HSS
【LCD-45.4t】稱重傳感器故障常用檢測方法
當計量系統(tǒng)出現(xiàn)故障現(xiàn)象后,我們可通過觀察和儀表測量等方法,確定儀表*和秤體處于完好狀態(tài)后,可做偏載測試以初步判斷哪只傳感器存在故障。
對傳感器好壞的檢測,我主要可以借助萬用表其性能、技術(shù)參數(shù)進行測量,與生產(chǎn)廠家使用說明書提供及平時檢修總結(jié)出來的技術(shù)數(shù)據(jù)進行對比,從而找出發(fā)生故障的傳感器,具體的檢測方法有:
1、阻抗判斷法:切斷工作電源,逐個將傳感器的輸出、輸入線拆開,若用萬用表測量輸出、輸入阻抗和信號電纜各芯與屏蔽層的絕緣性能(測量電阻值)下降,即可判斷出該只傳感器有故障。
注:電阻值根據(jù)具體的LCD-50t傳感器大小可能不同;如果根據(jù)以上的測量方法得出的電阻大小不等,傳感器多半損壞,應(yīng)更換。
2、輸出信號判斷法:
有時傳感器損壞,但阻抗并沒有很大變化,果采用阻抗法無法檢測出傳感器的好壞,可采用此法作進一步地檢測。給儀表送電后,逐個將傳感器的輸出線拆掉,需要注意的是在拆線過程中要特別小心操作以防觸電,且不可將輸出線與輸入激勵線短路,在空載情況下,用萬用表直流mV檔測其輸出線的mV值。
假定額定激勵電壓為U(V),傳感器的靈敏度為M(mV/V),傳感器載荷重量為K(kg),傳感器的額定容量為F(kg),則每只傳感器輸出電壓應(yīng)為:U×M×K/F(mV)
同一衡器同型號的傳感器在無載荷情況下其輸出mv值基本*。若超出計算值或傳感器的額定輸出且輸出不穩(wěn)定,即可判斷該只傳感器有故障。
注:公司目前使用的的傳感器靈敏度為2mV/V (稱重傳感器靈敏度用mV/V來表示,具體的含義是,當橋路激勵電壓輸入1V時對應(yīng)滿量程時的輸出電壓值)
3、排除法:如上兩種方法無法檢測出故障傳感器可用此法。將所有傳感器的連線拆掉,先接入一個LCD-50t傳感器的信號,如秤顯示正常,可將傳感器逐并聯(lián)接入,觀察顯示情況,接入某個后顯示不穩(wěn)定,則該只為故障傳感器。也可采用在通電情況下,逐個拆下傳感器的方法,當拆下某只傳感器、顯示正常了,那么剛拆下的那只傳感器就有故障。