純蒸汽發(fā)生器 Purity steam generator |
LCZ系列純蒸汽發(fā)生器,既能生產(chǎn)“飽和”純蒸汽,又能生產(chǎn)“過(guò)熱”純蒸汽,不僅是藥廠、保健飲品廠、醫(yī)院、生化科研等部門的消毒、滅菌的高純蒸汽生產(chǎn)專用設(shè)備,而且還是洗塞機(jī)、濕法消毒滅菌柜生產(chǎn)廠家的理想配套設(shè)備。
目前國(guó)內(nèi)外的純蒸汽發(fā)生器只能產(chǎn)出“飽和”純蒸汽,對(duì)于遠(yuǎn)距離(如100m以上)的設(shè)備進(jìn)行滅菌消毒時(shí),由于蒸汽到達(dá)使用點(diǎn)時(shí)已產(chǎn)生了大量的凝結(jié)水,已不屬于純蒸汽了,而是飽和水和飽和蒸汽的混合流體,因此滅菌消毒效果較差,尤其是300米以上的遠(yuǎn)距離工藝管道滅菌消毒,根本就達(dá)不到滅菌消毒的目的。
本產(chǎn)品配有“過(guò)熱”純蒸汽發(fā)生器,可產(chǎn)出“過(guò)熱”純蒸汽,對(duì)遠(yuǎn)距離的設(shè)備進(jìn)行滅菌消毒時(shí),“過(guò)熱”純蒸汽在到達(dá)使用點(diǎn)之前,流動(dòng)阻力和蒸汽管路散熱效應(yīng)可消除“過(guò)熱”純蒸汽的“過(guò)熱度”,轉(zhuǎn)換成不含凝結(jié)水的“飽和”純蒸汽,因此對(duì)(150—1000m)遠(yuǎn)距離的用汽點(diǎn)進(jìn)行滅菌消毒,仍具有時(shí)間短、效果好的優(yōu)點(diǎn)。對(duì)于遠(yuǎn)距離設(shè)備滅菌消毒,應(yīng)根據(jù)距離的增加適當(dāng)提高純蒸汽的“過(guò)熱度”,以保證純蒸汽的“過(guò)熱度”保持的時(shí)間長(zhǎng)一些,這樣也就保證了蒸汽到達(dá)使用點(diǎn)的純度。
LCZ series purity steam generator, both the production of "saturation" pure steam, while the production of "over-heating" pure steam, is not only the pharmaceutical, health care products factory, hospital, chemical and biological research and other departments can not be a lack of disinfection, sterilization of high-purity steam production of special equipment, but also a washing machine plug, wet disinfection and sterilization of the best cabinet manufacturers equipment.
At present, the pure steam generator at home and abroad can only output "saturation" pure steam, the long-range (for example,more than 100m) sterilization of the disinfection of equipment, due to arrive at the use of steam has been generated when a large amount of condensation water, has not are pure steam, but water and steam saturation of the mixed fluid, so the effect of very poor disinfection sterilization, in particular, more than 300 meters distance disinfection by steam sterilization equipment, there is simply not the purpose of disinfection sterilization.
This product is equipped with "overheating" pure steam generator, can be output "overheating" pure steam, on the long-distance sterile equipment, the "overheating" pure steam before reaching the point-of-use, flow resistance and heat dissipation effect of the steam pipe may be the elimination of "overheating" pure steam "superheat", without condensation of water into the "saturation" pure steam, so (150-2000m) distance of the points with steam sterilization disinfection, is still short, the advantages of good effect, the advantages are all at home and abroad do not have pure steam generator, and it is the patented product innovation. Sterile equipment for long-distance, the distance should be based on an appropriate increase in net increase in steam "superheat" in order to ensure pure steam of "overheating" of maintaining longer, and thus arrive at the use of steam to ensure purity point.