技術參數(shù):
NO | Technical requirement | Technical parameter | Remarks |
1 | 設備內(nèi)腔表面粗糙度/Surface roughness of the inner cavity of equipment | Ra≤0.5um |
|
2 | 無菌傳遞總時間/Total time of aseptic transfer | 100-120min | The full load |
3 | 除濕總時間/Total dehumidification time | 30-45min |
|
4 | 滅菌總時間/Total sterilization time | 30-45min |
|
5 | 通風總時間/Total ventilation time | 60-90min |
|
6 | 滅菌濃度/Sterilizing concentration | 150-400PPM |
|
7 | 滅菌后殘留VHP濃度標準/Standard of residual VHP concentration after sterilization | ≤1ppm |
|
8 | 內(nèi)腔材質(zhì)/Inner cavity material | SUS304/T2.0mm |
|
9 | 設備外表面材質(zhì)/External surface material of equipment | SUS304 |
|
10 | 換氣次數(shù)/Air change times | 150-200pcs |
|
11 | 設備運行階段內(nèi)部潔凈等級/Internal cleanliness grade of equipment operation stage | A級 |
|
12 | 設備泄露率/Equipment leakage rate | ≤0.5% |
|
13 | 噪聲級別/Noise level | ≤75db |
|
14 | 滅菌效果/Sterilization effect | 6LOG |
|
15 | 總功率(W)/Total power (W) | ≤3500W |
|
16 | 非金屬材料/Nonmetallic materials | (PTFE)、Silica gel、Tempered glass |
|
17 | 汽化溫度/Vaporization temperature | ≤100℃ |
|
18 | 重量/Weight | 600KG |
|
19 | 體積/volume | 見方案 |
工藝描述
過氧化氫傳遞窗用于無菌物料由C/D級潔凈區(qū)向A/B級潔凈區(qū)傳遞時,去除物品或容器表面的生物污染。共分三個步驟:
步驟1:物品或容器在C/D級區(qū)域放到傳遞窗內(nèi)(放置時物品之間留有間隙,保證物品或容器限度的暴露在空氣中,不留滅菌死角),關閉窗門后進行下一步。
步驟2:關好窗門后接通電源,開啟儀器進行滅菌,可選用手動和自動運行程序兩種模式,手動模式下分為除濕、調(diào)節(jié)、滅菌、排殘、通風、保壓六個步驟,其中汽化溫度設定為95℃左右,調(diào)節(jié)周期和滅菌周期可根據(jù)實際情況進行設定,排殘時間或通風時間可設置,調(diào)節(jié)間歇和滅菌間歇設置可設置,保壓壓差設定范圍10pa-60pa。在滅菌過程中,傳遞窗內(nèi)的過氧化氫濃度傳感器可實時監(jiān)控窗內(nèi)過氧化氫濃度。
步驟3:滅菌結(jié)束后,打開A/B級潔凈區(qū)的傳遞門,從傳遞窗內(nèi)取出被滅物品。